@@ -0,0 +1,515 @@
|
||||
# System Requirements Specification (SRS)
|
||||
# ASF Sensor Hub (Sub-Hub) Embedded System
|
||||
|
||||
**Document Type:** System Requirements Specification
|
||||
**Version:** 1.0
|
||||
**Date:** 2025-01-19
|
||||
**Platform:** ESP32-S3, ESP-IDF v5.4, C/C++
|
||||
**Domain:** Industrial/Agricultural Automation (Smart Poultry Farm)
|
||||
**Standard:** ISO/IEC/IEEE 29148:2018
|
||||
|
||||
## 1. Introduction
|
||||
|
||||
### 1.1 Purpose
|
||||
|
||||
This System Requirements Specification (SRS) defines the complete set of system requirements for the ASF Sensor Hub (Sub-Hub) embedded system. The document serves as the authoritative source for all functional and non-functional requirements that the system must satisfy.
|
||||
|
||||
### 1.2 Scope
|
||||
|
||||
The ASF Sensor Hub is a distributed sensing node deployed inside a poultry house for environmental monitoring and data collection. The system is responsible for:
|
||||
|
||||
- Acquisition of multiple environmental sensor data
|
||||
- Local preprocessing and validation of sensor data
|
||||
- Persistent storage of data and configuration
|
||||
- Secure communication with a Main Hub
|
||||
- Support for diagnostics, maintenance, and OTA updates
|
||||
- Safe operation under fault conditions
|
||||
|
||||
**Explicitly out of scope:**
|
||||
- Main Hub processing and control logic
|
||||
- Cloud analytics and services
|
||||
- Farm control algorithms
|
||||
- Actuator management
|
||||
|
||||
### 1.3 Definitions and Acronyms
|
||||
|
||||
| Term | Definition |
|
||||
|------|------------|
|
||||
| **Sub-Hub** | The ASF Sensor Hub embedded system (this system) |
|
||||
| **Main Hub** | Central processing unit that coordinates multiple Sub-Hubs |
|
||||
| **MC** | Machine Constants - persistent configuration data |
|
||||
| **DP** | Data Persistence component |
|
||||
| **STM** | State Manager component |
|
||||
| **SAL** | Sensor Abstraction Layer |
|
||||
| **HMI** | Human-Machine Interface (OLED display + buttons) |
|
||||
| **OTA** | Over-The-Air firmware update |
|
||||
| **mTLS** | Mutual Transport Layer Security |
|
||||
| **CBOR** | Concise Binary Object Representation |
|
||||
|
||||
### 1.4 References
|
||||
|
||||
- ISO/IEC/IEEE 29148:2018 - Systems and software engineering — Life cycle processes — Requirements engineering
|
||||
- IEC 61508 - Functional safety of electrical/electronic/programmable electronic safety-related systems
|
||||
- ESP-IDF v5.4 Programming Guide
|
||||
- System_Architecture_Documentation.md
|
||||
- Cross-Feature Constraints.md
|
||||
|
||||
## 2. Overall Description
|
||||
|
||||
### 2.1 Product Perspective
|
||||
|
||||
The ASF Sensor Hub operates as an autonomous embedded system within a distributed poultry farm automation network. It interfaces with:
|
||||
|
||||
- **Environmental sensors** via I2C, SPI, UART, and analog interfaces
|
||||
- **Main Hub** via encrypted Wi-Fi communication
|
||||
- **Peer Sub-Hubs** via ESP-NOW for limited coordination
|
||||
- **Local operators** via OLED display and button interface
|
||||
- **SD Card** for persistent data storage
|
||||
|
||||
### 2.2 Product Functions
|
||||
|
||||
The system provides the following major functions:
|
||||
|
||||
1. **Multi-sensor data acquisition** with high-frequency sampling and filtering
|
||||
2. **Data quality assurance** through calibration and failure detection
|
||||
3. **Secure communication** with Main Hub using encrypted protocols
|
||||
4. **Persistent data storage** with wear-aware management
|
||||
5. **Over-the-air firmware updates** with rollback capability
|
||||
6. **Comprehensive diagnostics** and health monitoring
|
||||
7. **Local human-machine interface** for status and diagnostics
|
||||
8. **System state management** with controlled transitions
|
||||
9. **Security enforcement** through hardware-based protection
|
||||
10. **Power and fault handling** with graceful degradation
|
||||
|
||||
### 2.3 User Classes and Characteristics
|
||||
|
||||
| User Class | Characteristics | System Interaction |
|
||||
|------------|-----------------|-------------------|
|
||||
| **Farm Operators** | Basic technical knowledge, daily monitoring | Local HMI for status checking |
|
||||
| **Maintenance Engineers** | Advanced technical knowledge, periodic maintenance | Debug sessions, diagnostic access |
|
||||
| **System Integrators** | Expert technical knowledge, system configuration | Machine constants management, OTA updates |
|
||||
|
||||
### 2.4 Operating Environment
|
||||
|
||||
- **Hardware Platform:** ESP32-S3 microcontroller
|
||||
- **Operating System:** FreeRTOS (via ESP-IDF)
|
||||
- **Development Framework:** ESP-IDF v5.4
|
||||
- **Programming Language:** C/C++
|
||||
- **Environmental Conditions:** Industrial poultry house (temperature, humidity, dust)
|
||||
- **Power Supply:** 12V DC with brownout protection
|
||||
- **Communication:** Wi-Fi 802.11n (2.4 GHz), ESP-NOW
|
||||
|
||||
### 2.5 Design and Implementation Constraints
|
||||
|
||||
- **Memory:** 512KB SRAM, 8MB Flash (ESP32-S3)
|
||||
- **Real-time:** Deterministic sensor sampling within 1-second cycles
|
||||
- **Security:** Hardware-enforced Secure Boot V2 and Flash Encryption
|
||||
- **Reliability:** 99.9% uptime requirement in normal operating conditions
|
||||
- **Safety:** IEC 61508 SIL-1 compliance for sensor data integrity
|
||||
- **Environmental:** IP65 enclosure rating, -10°C to +60°C operating range
|
||||
|
||||
## 3. System Requirements
|
||||
|
||||
### 3.1 Functional Requirements
|
||||
|
||||
#### 3.1.1 Sensor Data Acquisition Requirements
|
||||
|
||||
**SR-DAQ-001: Multi-Sensor Support**
|
||||
The system SHALL support simultaneous data acquisition from the following sensor types:
|
||||
- Temperature sensors
|
||||
- Humidity sensors
|
||||
- Carbon Dioxide (CO₂) sensors
|
||||
- Ammonia (NH₃) sensors
|
||||
- Volatile Organic Compounds (VOC) sensors
|
||||
- Particulate Matter (PM) sensors
|
||||
- Light Intensity sensors
|
||||
|
||||
**SR-DAQ-002: High-Frequency Sampling**
|
||||
The system SHALL sample each enabled sensor a minimum of 10 times per acquisition cycle to enable local filtering.
|
||||
|
||||
**SR-DAQ-003: Local Data Filtering**
|
||||
The system SHALL apply configurable filtering algorithms (median filter, moving average) to raw sensor samples to produce representative values.
|
||||
|
||||
**SR-DAQ-004: Timestamped Data Generation**
|
||||
The system SHALL associate each processed sensor value with a timestamp accurate to ±1 second of system time.
|
||||
|
||||
**SR-DAQ-005: Sensor State Management**
|
||||
The system SHALL maintain operational state for each sensor (enabled/disabled, present/absent, healthy/faulty).
|
||||
|
||||
#### 3.1.2 Data Quality & Calibration Requirements
|
||||
|
||||
**SR-DQC-001: Automatic Sensor Detection**
|
||||
The system SHALL automatically detect the presence of sensors based on hardware detection signals during initialization and runtime.
|
||||
|
||||
**SR-DQC-002: Sensor Type Enforcement**
|
||||
The system SHALL enforce sensor-slot compatibility to prevent incorrect sensor installation and usage.
|
||||
|
||||
**SR-DQC-003: Sensor Failure Detection**
|
||||
The system SHALL detect sensor failures including communication errors, out-of-range values, and non-responsive sensors.
|
||||
|
||||
**SR-DQC-004: Machine Constants Management**
|
||||
The system SHALL maintain persistent Machine Constants (MC) data including:
|
||||
- Installed sensor type definitions
|
||||
- Sensor calibration parameters
|
||||
- Communication configuration parameters
|
||||
- System identity parameters
|
||||
|
||||
**SR-DQC-005: Calibration Parameter Application**
|
||||
The system SHALL apply calibration parameters from MC data to raw sensor readings to produce calibrated values.
|
||||
|
||||
#### 3.1.3 Communication Requirements
|
||||
|
||||
**SR-COM-001: Main Hub Communication**
|
||||
The system SHALL provide bidirectional encrypted communication with a Main Hub to:
|
||||
- Send sensor data using CBOR encoding
|
||||
- Send diagnostic information
|
||||
- Receive configuration updates
|
||||
- Receive firmware updates
|
||||
|
||||
**SR-COM-002: Secure Communication Protocols**
|
||||
The system SHALL use mTLS 1.2 with X.509 certificates for all Main Hub communication.
|
||||
|
||||
**SR-COM-003: On-Demand Data Broadcasting**
|
||||
The system SHALL transmit the most recent sensor dataset upon request from the Main Hub within 5 seconds.
|
||||
|
||||
**SR-COM-004: Peer Communication**
|
||||
The system SHALL support limited peer-to-peer communication with other Sub-Hubs using ESP-NOW for:
|
||||
- Connectivity checks
|
||||
- Time synchronization support
|
||||
- Basic status exchange
|
||||
|
||||
**SR-COM-005: Communication Fault Tolerance**
|
||||
The system SHALL continue autonomous operation during Main Hub communication failures for up to 24 hours.
|
||||
|
||||
#### 3.1.4 Persistence & Data Management Requirements
|
||||
|
||||
**SR-DATA-001: Persistent Sensor Data Storage**
|
||||
The system SHALL store sensor data persistently on SD Card using FAT32 file system with wear-aware batch writing.
|
||||
|
||||
**SR-DATA-002: Data Persistence Abstraction**
|
||||
The system SHALL provide a unified Data Persistence (DP) component that abstracts storage media access for all persistent data operations.
|
||||
|
||||
**SR-DATA-003: Safe Data Handling During Transitions**
|
||||
The system SHALL ensure all critical data is safely persisted before:
|
||||
- Firmware updates
|
||||
- Configuration updates
|
||||
- System teardown
|
||||
- Reset or restart operations
|
||||
|
||||
**SR-DATA-004: Data Integrity Protection**
|
||||
The system SHALL implement data integrity mechanisms including checksums and atomic write operations to prevent data corruption.
|
||||
|
||||
**SR-DATA-005: Storage Capacity Management**
|
||||
The system SHALL manage storage capacity by implementing circular logging with configurable retention periods.
|
||||
|
||||
#### 3.1.5 Firmware Update (OTA) Requirements
|
||||
|
||||
**SR-OTA-001: OTA Update Negotiation**
|
||||
The system SHALL implement an OTA handshake mechanism with the Main Hub to acknowledge update availability and signal readiness.
|
||||
|
||||
**SR-OTA-002: Firmware Reception and Storage**
|
||||
The system SHALL securely receive firmware images and store them temporarily on SD Card before activation.
|
||||
|
||||
**SR-OTA-003: Firmware Integrity Validation**
|
||||
The system SHALL validate firmware integrity using SHA-256 checksums before activation.
|
||||
|
||||
**SR-OTA-004: Safe Firmware Activation**
|
||||
The system SHALL implement A/B partitioning with automatic rollback capability for safe firmware activation.
|
||||
|
||||
**SR-OTA-005: OTA State Management**
|
||||
The system SHALL coordinate OTA operations with the system state machine to ensure safe transitions and data preservation.
|
||||
|
||||
#### 3.1.6 Security & Safety Requirements
|
||||
|
||||
**SR-SEC-001: Secure Boot**
|
||||
The system SHALL implement Secure Boot V2 to ensure only authenticated firmware is executed.
|
||||
|
||||
**SR-SEC-002: Flash Encryption**
|
||||
The system SHALL implement Flash Encryption using AES-256 to protect sensitive data and intellectual property.
|
||||
|
||||
**SR-SEC-003: Certificate Management**
|
||||
The system SHALL manage X.509 certificates for mTLS communication with secure storage and validation.
|
||||
|
||||
**SR-SEC-004: Security Violation Handling**
|
||||
The system SHALL detect and respond to security violations including:
|
||||
- Boot verification failures
|
||||
- Certificate validation failures
|
||||
- Unauthorized access attempts
|
||||
|
||||
#### 3.1.7 Diagnostics & Health Monitoring Requirements
|
||||
|
||||
**SR-DIAG-001: Diagnostic Code Management**
|
||||
The system SHALL implement structured diagnostics with:
|
||||
- Unique diagnostic codes (format: 0xSCCC)
|
||||
- Severity levels (INFO, WARNING, ERROR, FATAL)
|
||||
- Root cause hierarchy
|
||||
- Timestamp information
|
||||
|
||||
**SR-DIAG-002: Diagnostic Data Storage**
|
||||
The system SHALL persistently store diagnostic events in a circular log with configurable retention.
|
||||
|
||||
**SR-DIAG-003: Diagnostic Session Support**
|
||||
The system SHALL provide diagnostic sessions allowing authorized engineers to:
|
||||
- Retrieve diagnostic data
|
||||
- Inspect system health status
|
||||
- Clear diagnostic records
|
||||
|
||||
**SR-DIAG-004: Layered Watchdog System**
|
||||
The system SHALL implement multiple watchdog levels:
|
||||
- Task-level watchdogs for critical tasks
|
||||
- Interrupt watchdog for system responsiveness
|
||||
- RTC watchdog for ultimate system recovery
|
||||
|
||||
#### 3.1.8 System Management Requirements
|
||||
|
||||
**SR-SYS-001: System State Machine**
|
||||
The system SHALL implement a finite state machine with the following states:
|
||||
- INIT, BOOT_FAILURE, RUNNING, WARNING, FAULT
|
||||
- OTA_PREP, OTA_UPDATE, MC_UPDATE, TEARDOWN
|
||||
- SERVICE, SD_DEGRADED
|
||||
|
||||
**SR-SYS-002: State-Aware Operation**
|
||||
The system SHALL restrict feature operations based on current system state according to defined state transition rules.
|
||||
|
||||
**SR-SYS-003: Controlled Teardown**
|
||||
The system SHALL execute a controlled teardown sequence that:
|
||||
- Stops sensor acquisition
|
||||
- Flushes all critical data
|
||||
- Ensures storage consistency
|
||||
- Prepares for target state transition
|
||||
|
||||
**SR-SYS-004: Local Human-Machine Interface**
|
||||
The system SHALL provide local status indication using:
|
||||
- OLED display (128x64, I2C interface)
|
||||
- Three-button navigation (Up, Down, Select)
|
||||
- Menu system for diagnostics and sensor status
|
||||
|
||||
**SR-SYS-005: Engineering Access**
|
||||
The system SHALL support authenticated engineering sessions for:
|
||||
- Log inspection
|
||||
- Machine constants inspection and update
|
||||
- Controlled debugging operations
|
||||
|
||||
#### 3.1.9 Power & Fault Handling Requirements
|
||||
|
||||
**SR-PWR-001: Brownout Detection**
|
||||
The system SHALL detect power supply brownout conditions and initiate controlled shutdown procedures.
|
||||
|
||||
**SR-PWR-002: Power-Loss Recovery**
|
||||
The system SHALL implement power-loss recovery mechanisms to restore operation after power restoration.
|
||||
|
||||
**SR-PWR-003: Fault Classification**
|
||||
The system SHALL classify faults into categories:
|
||||
- Sensor faults, Communication faults, Storage faults
|
||||
- Power faults, Security faults, Software faults, Hardware faults
|
||||
|
||||
**SR-PWR-004: Fault Escalation**
|
||||
The system SHALL implement fault escalation procedures based on severity and frequency.
|
||||
|
||||
#### 3.1.10 Hardware Abstraction Requirements
|
||||
|
||||
**SR-HW-001: Sensor Abstraction Layer**
|
||||
The system SHALL implement a Sensor Abstraction Layer (SAL) that provides uniform interfaces for different sensor types.
|
||||
|
||||
**SR-HW-002: Hardware Interface Abstraction**
|
||||
The system SHALL abstract hardware interfaces (GPIO, I2C, SPI, UART, ADC) through driver layers to enable portability.
|
||||
|
||||
**SR-HW-003: GPIO Discipline**
|
||||
The system SHALL implement GPIO discipline with defined ownership and access control for hardware resources.
|
||||
|
||||
### 3.2 Non-Functional Requirements
|
||||
|
||||
#### 3.2.1 Performance Requirements
|
||||
|
||||
**SR-PERF-001: Sensor Acquisition Timing**
|
||||
The system SHALL complete sensor acquisition cycles within 1 second for all enabled sensors.
|
||||
|
||||
**SR-PERF-002: Communication Response Time**
|
||||
The system SHALL respond to Main Hub requests within 5 seconds under normal operating conditions.
|
||||
|
||||
**SR-PERF-003: Memory Usage**
|
||||
The system SHALL operate within 80% of available SRAM (409.6KB) and Flash (6.4MB) capacity.
|
||||
|
||||
**SR-PERF-004: Storage Performance**
|
||||
The system SHALL achieve minimum 10KB/s write performance to SD Card for data logging.
|
||||
|
||||
#### 3.2.2 Reliability Requirements
|
||||
|
||||
**SR-REL-001: System Availability**
|
||||
The system SHALL achieve 99.9% availability during normal operating conditions.
|
||||
|
||||
**SR-REL-002: Mean Time Between Failures**
|
||||
The system SHALL achieve MTBF of 8760 hours (1 year) under specified environmental conditions.
|
||||
|
||||
**SR-REL-003: Fault Recovery**
|
||||
The system SHALL automatically recover from transient faults within 30 seconds.
|
||||
|
||||
**SR-REL-004: Data Integrity**
|
||||
The system SHALL maintain data integrity with error rate < 1 in 10^6 operations.
|
||||
|
||||
#### 3.2.3 Safety Requirements
|
||||
|
||||
**SR-SAFE-001: Fail-Safe Operation**
|
||||
The system SHALL fail to a safe state (sensor data marked invalid) upon detection of critical faults.
|
||||
|
||||
**SR-SAFE-002: Sensor Data Validation**
|
||||
The system SHALL validate sensor data ranges and mark out-of-range values as invalid.
|
||||
|
||||
**SR-SAFE-003: Watchdog Protection**
|
||||
The system SHALL implement multiple watchdog mechanisms to detect and recover from software failures.
|
||||
|
||||
#### 3.2.4 Security Requirements
|
||||
|
||||
**SR-SEC-005: Authentication**
|
||||
The system SHALL authenticate all external communication using certificate-based mutual authentication.
|
||||
|
||||
**SR-SEC-006: Data Encryption**
|
||||
The system SHALL encrypt all sensitive data at rest using AES-256 encryption.
|
||||
|
||||
**SR-SEC-007: Secure Communication**
|
||||
The system SHALL encrypt all network communication using TLS 1.2 or higher.
|
||||
|
||||
**SR-SEC-008: Access Control**
|
||||
The system SHALL implement role-based access control for engineering and diagnostic functions.
|
||||
|
||||
#### 3.2.5 Maintainability Requirements
|
||||
|
||||
**SR-MAINT-001: Diagnostic Accessibility**
|
||||
The system SHALL provide comprehensive diagnostic information accessible through local and remote interfaces.
|
||||
|
||||
**SR-MAINT-002: Configuration Management**
|
||||
The system SHALL support field configuration updates through authenticated channels.
|
||||
|
||||
**SR-MAINT-003: Firmware Updateability**
|
||||
The system SHALL support secure over-the-air firmware updates with rollback capability.
|
||||
|
||||
#### 3.2.6 Portability Requirements
|
||||
|
||||
**SR-PORT-001: Hardware Abstraction**
|
||||
The system SHALL abstract hardware dependencies to enable porting to compatible microcontroller platforms.
|
||||
|
||||
**SR-PORT-002: Standard Interfaces**
|
||||
The system SHALL use standard communication protocols (I2C, SPI, UART) for sensor interfaces.
|
||||
|
||||
### 3.3 Interface Requirements
|
||||
|
||||
#### 3.3.1 Hardware Interfaces
|
||||
|
||||
**SR-HW-IF-001: Sensor Interfaces**
|
||||
The system SHALL provide the following sensor interfaces:
|
||||
- 4x I2C interfaces for digital sensors
|
||||
- 2x SPI interfaces for high-speed sensors
|
||||
- 2x UART interfaces for serial sensors
|
||||
- 4x ADC channels for analog sensors
|
||||
|
||||
**SR-HW-IF-002: Communication Interfaces**
|
||||
The system SHALL provide:
|
||||
- Wi-Fi 802.11n (2.4 GHz) interface
|
||||
- Optional Zigbee/LoRa interface for backup communication
|
||||
|
||||
**SR-HW-IF-003: Storage Interfaces**
|
||||
The system SHALL provide:
|
||||
- SD Card interface (SPI-based)
|
||||
- Internal NVM (encrypted)
|
||||
|
||||
**SR-HW-IF-004: User Interface**
|
||||
The system SHALL provide:
|
||||
- OLED display interface (I2C, 128x64 pixels)
|
||||
- 3x GPIO inputs for buttons (Up, Down, Select)
|
||||
|
||||
#### 3.3.2 Software Interfaces
|
||||
|
||||
**SR-SW-IF-001: Main Hub Protocol**
|
||||
The system SHALL implement the Main Hub communication protocol using:
|
||||
- MQTT over TLS 1.2 transport
|
||||
- CBOR message encoding
|
||||
- Defined message schemas for sensor data, diagnostics, and control
|
||||
|
||||
**SR-SW-IF-002: Peer Communication Protocol**
|
||||
The system SHALL implement peer communication using ESP-NOW protocol with defined message formats.
|
||||
|
||||
**SR-SW-IF-003: Diagnostic Interface**
|
||||
The system SHALL provide diagnostic interface supporting:
|
||||
- Log retrieval commands
|
||||
- System status queries
|
||||
- Configuration inspection commands
|
||||
|
||||
## 4. System Architecture Requirements
|
||||
|
||||
### 4.1 Architectural Constraints
|
||||
|
||||
**SR-ARCH-001: Layered Architecture**
|
||||
The system SHALL implement a strict layered architecture with dependency flow from Application → Drivers → OSAL → HAL.
|
||||
|
||||
**SR-ARCH-002: Hardware Abstraction**
|
||||
Application logic SHALL NOT access hardware directly and SHALL use driver abstractions exclusively.
|
||||
|
||||
**SR-ARCH-003: State-Aware Execution**
|
||||
All system features SHALL be aware of current system state and respect state-based operation restrictions.
|
||||
|
||||
**SR-ARCH-004: Event-Driven Communication**
|
||||
Internal component communication SHALL use event-driven publish/subscribe mechanisms.
|
||||
|
||||
**SR-ARCH-005: Data Persistence Abstraction**
|
||||
All persistent data access SHALL be performed through the Data Persistence (DP) component.
|
||||
|
||||
### 4.2 Component Requirements
|
||||
|
||||
**SR-COMP-001: State Manager Component**
|
||||
The system SHALL implement a State Manager (STM) component responsible for:
|
||||
- System state machine implementation
|
||||
- State transition validation and coordination
|
||||
- Teardown sequence management
|
||||
|
||||
**SR-COMP-002: Event System Component**
|
||||
The system SHALL implement an Event System component providing:
|
||||
- Publish/subscribe event bus
|
||||
- Non-blocking event delivery
|
||||
- Event type management
|
||||
|
||||
**SR-COMP-003: Sensor Manager Component**
|
||||
The system SHALL implement a Sensor Manager component responsible for:
|
||||
- Sensor lifecycle management
|
||||
- Data acquisition scheduling
|
||||
- Local filtering and validation
|
||||
|
||||
**SR-COMP-004: Data Persistence Component**
|
||||
The system SHALL implement a Data Persistence (DP) component providing:
|
||||
- Storage media abstraction
|
||||
- Data serialization/deserialization
|
||||
- Wear-aware storage management
|
||||
|
||||
## 5. Verification Requirements
|
||||
|
||||
### 5.1 Verification Methods
|
||||
|
||||
Each system requirement SHALL be verified using one or more of the following methods:
|
||||
- **Test (T):** Verification by test execution
|
||||
- **Analysis (A):** Verification by analysis or calculation
|
||||
- **Inspection (I):** Verification by inspection or review
|
||||
- **Demonstration (D):** Verification by demonstration
|
||||
|
||||
### 5.2 Verification Levels
|
||||
|
||||
- **Unit Level:** Individual component verification
|
||||
- **Integration Level:** Component interaction verification
|
||||
- **System Level:** End-to-end system verification
|
||||
- **Acceptance Level:** User acceptance verification
|
||||
|
||||
## 6. Traceability
|
||||
|
||||
This SRS provides the foundation for:
|
||||
- Software Requirements Specification (SWR-XXX requirements)
|
||||
- Feature specifications (F-XXX features)
|
||||
- Component specifications (C-XXX components)
|
||||
- Test specifications and procedures
|
||||
|
||||
All system requirements SHALL be traceable to:
|
||||
- Stakeholder needs and use cases
|
||||
- Feature definitions in Features.md
|
||||
- Architectural constraints in Cross-Feature Constraints.md
|
||||
|
||||
---
|
||||
|
||||
**Document Status:** Final for Implementation Phase
|
||||