# Feature Engineering Specification
|
||||
|
||||
## Persistence & Data Management Features
|
||||
|
||||
**Feature Group ID:** FG-DATA
|
||||
**Scope:** Sensor Hub (Sub-Hub only)
|
||||
**Target Platform:** ESP32-S3–based Sensor Hub
|
||||
**Applies To:** Indoor poultry farm sensor hubs
|
||||
**Dependencies:**
|
||||
|
||||
* Sensor Data Acquisition (FG-DAQ)
|
||||
|
||||
* Data Quality & Calibration (FG-DQC)
|
||||
|
||||
* Diagnostics & Health Monitoring (FG-DIAG)
|
||||
|
||||
* System State Management / Teardown Mechanism
|
||||
|
||||
|
||||
## 1\. Purpose and Objectives
|
||||
|
||||
The **Persistence & Data Management Features** define how the Sensor Hub stores, protects, and manages critical runtime and historical data. These features ensure that:
|
||||
|
||||
* Sensor data and system state are not lost during resets or failures
|
||||
|
||||
* Data storage is abstracted from application logic
|
||||
|
||||
* Critical data is safely handled during firmware updates, configuration changes, or fatal faults
|
||||
|
||||
|
||||
The persistence layer is a **foundational system service**, supporting diagnostics, calibration, OTA, and recovery operations.
|
||||
|
||||
## 2\. Feature Overview and Relationships
|
||||
|
||||
<figure class="table op-uc-figure_align-center op-uc-figure"><table class="op-uc-table"><thead class="op-uc-table--head"><tr class="op-uc-table--row"><th class="op-uc-table--cell op-uc-table--cell_head"><p class="op-uc-p">Feature ID</p></th><th class="op-uc-table--cell op-uc-table--cell_head"><p class="op-uc-p">Feature Name</p></th><th class="op-uc-table--cell op-uc-table--cell_head"><p class="op-uc-p">Primary Objective</p></th><th class="op-uc-table--cell op-uc-table--cell_head"><p class="op-uc-p">Related Features</p></th></tr></thead><tbody><tr class="op-uc-table--row"><td class="op-uc-table--cell"><p class="op-uc-p">F-DATA-01</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Persistent Sensor Data Storage</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Store timestamped sensor data</p></td><td class="op-uc-table--cell"><p class="op-uc-p">DAQ, COM</p></td></tr><tr class="op-uc-table--row"><td class="op-uc-table--cell"><p class="op-uc-p">F-DATA-02</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Data Persistence Abstraction (DP)</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Abstract storage access</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Application Layer</p></td></tr><tr class="op-uc-table--row"><td class="op-uc-table--cell"><p class="op-uc-p">F-DATA-03</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Safe Data Handling During State Transitions</p></td><td class="op-uc-table--cell"><p class="op-uc-p">Protect data during teardown</p></td><td class="op-uc-table--cell"><p class="op-uc-p">OTA, System Mgmt</p></td></tr></tbody></table></figure>
|
||||
|
||||
## 3\. Functional Feature Descriptions
|
||||
|
||||
### 3.1 F-DATA-01: Persistent Sensor Data Storage
|
||||
|
||||
**Description**
|
||||
The system shall persist timestamped sensor data to non-volatile storage to support historical analysis, diagnostics correlation, and recovery scenarios.
|
||||
|
||||
Persistence may include:
|
||||
|
||||
* Filtered sensor values
|
||||
|
||||
* Timestamps
|
||||
|
||||
* Sensor validity and status metadata
|
||||
|
||||
|
||||
The persistence policy (frequency, retention window, overwrite behavior) is configurable and optimized for storage longevity and performance.
|
||||
|
||||
**Key Capabilities**
|
||||
|
||||
* Non-volatile storage (SD card / NVM)
|
||||
|
||||
* Timestamped records
|
||||
|
||||
* Configurable retention policy
|
||||
|
||||
* Integration with DAQ and COM
|
||||
|
||||
|
||||
### 3.2 F-DATA-02: Data Persistence Abstraction (DP Component)
|
||||
|
||||
**Description**
|
||||
The system shall provide a **Data Persistence (DP) component** that abstracts storage access for all upper layers. Application and feature modules interact with the DP component rather than directly accessing storage hardware.
|
||||
|
||||
The DP component manages:
|
||||
|
||||
* Data model definitions
|
||||
|
||||
* Serialization and deserialization
|
||||
|
||||
* Storage backend selection
|
||||
|
||||
* Consistency and integrity guarantees
|
||||
|
||||
|
||||
**Key Capabilities**
|
||||
|
||||
* Unified persistence API
|
||||
|
||||
* Storage backend abstraction
|
||||
|
||||
* Centralized data ownership
|
||||
|
||||
* Reduced coupling between layers
|
||||
|
||||
|
||||
### 3.3 F-DATA-03: Safe Data Handling During State Transitions
|
||||
|
||||
**Description**
|
||||
The system shall ensure safe and deterministic handling of data during critical state transitions, including:
|
||||
|
||||
* Firmware updates (OTA)
|
||||
|
||||
* Machine Constants updates
|
||||
|
||||
* System resets
|
||||
|
||||
* Fatal error handling
|
||||
|
||||
|
||||
Before entering such transitions, the system executes a controlled data finalization process to flush buffers, persist critical state, and verify data integrity.
|
||||
|
||||
**Key Capabilities**
|
||||
|
||||
* Controlled data flush
|
||||
|
||||
* Atomic write operations
|
||||
|
||||
* Data integrity checks
|
||||
|
||||
* Coordination with teardown mechanism
|
||||
|
||||
|
||||
## 4\. System Requirements (Formal SHALL Statements)
|
||||
|
||||
### 4.1 Persistent Sensor Data Storage
|
||||
|
||||
**SR-DATA-001**
|
||||
The system shall persist timestamped sensor data in non-volatile storage.
|
||||
|
||||
**SR-DATA-002**
|
||||
The system shall store sensor data together with sensor identifiers, timestamps, and validity status.
|
||||
|
||||
**SR-DATA-003**
|
||||
The system shall support configurable data retention and overwrite policies.
|
||||
|
||||
### 4.2 Data Persistence Abstraction (DP Component)
|
||||
|
||||
**SR-DATA-004**
|
||||
The system shall provide a Data Persistence (DP) component as the sole interface for persistent data access.
|
||||
|
||||
**SR-DATA-005**
|
||||
The system shall prevent application and feature modules from directly accessing storage hardware.
|
||||
|
||||
**SR-DATA-006**
|
||||
The DP component shall support serialization and deserialization of structured system data.
|
||||
|
||||
### 4.3 Safe Data Handling During State Transitions
|
||||
|
||||
**SR-DATA-007**
|
||||
The system shall ensure that all critical runtime data is flushed to non-volatile storage before entering a controlled teardown or reset.
|
||||
|
||||
**SR-DATA-008**
|
||||
The system shall protect data integrity during firmware updates and configuration changes.
|
||||
|
||||
**SR-DATA-009**
|
||||
The system shall verify successful data persistence before completing a state transition.
|
||||
|
||||
## 5\. Feature ↔ System Requirement Mapping
|
||||
|
||||
<figure class="table op-uc-figure_align-center op-uc-figure"><table class="op-uc-table"><thead class="op-uc-table--head"><tr class="op-uc-table--row"><th class="op-uc-table--cell op-uc-table--cell_head"><p class="op-uc-p">Feature ID</p></th><th class="op-uc-table--cell op-uc-table--cell_head"><p class="op-uc-p">System Requirements</p></th></tr></thead><tbody><tr class="op-uc-table--row"><td class="op-uc-table--cell"><p class="op-uc-p">F-DATA-01</p></td><td class="op-uc-table--cell"><p class="op-uc-p">SR-DATA-001, SR-DATA-002, SR-DATA-003</p></td></tr><tr class="op-uc-table--row"><td class="op-uc-table--cell"><p class="op-uc-p">F-DATA-02</p></td><td class="op-uc-table--cell"><p class="op-uc-p">SR-DATA-004, SR-DATA-005, SR-DATA-006</p></td></tr><tr class="op-uc-table--row"><td class="op-uc-table--cell"><p class="op-uc-p">F-DATA-03</p></td><td class="op-uc-table--cell"><p class="op-uc-p">SR-DATA-007, SR-DATA-008, SR-DATA-009</p></td></tr></tbody></table></figure>
|
||||
|
||||
## 6\. Engineering Notes
|
||||
|
||||
* The DP component aligns with your **DP Stack** already defined in the architecture.
|
||||
|
||||
* Atomic write strategies (e.g., temp file + rename) are recommended.
|
||||
|
||||
* Diagnostic events should be generated on persistence failures.
|
||||
|
||||
* Storage wear-leveling considerations apply for SD/NVM.
|
||||
|
||||
|
||||
##
|
||||