# Feature Engineering Specification ## Diagnostics & Health Monitoring Features **Feature Group ID:** FG-DIAG **Scope:** Sensor Hub (Sub-Hub only) **Target Platform:** ESP32-S3–based Sensor Hub **Applies To:** Indoor poultry farm sensor hubs **Dependencies:** * Sensor Data Acquisition (FG-DAQ) * Data Quality & Calibration (FG-DQC) * Communication Features (FG-COM) * Persistence / DP Stack ## 1\. Purpose and Objectives The **Diagnostics & Health Monitoring Features** provide a structured and persistent mechanism to detect, classify, record, and expose system faults, warnings, and health states. These features ensure that: * Failures are detectable and explainable * Root causes are traceable * Diagnostic data survives resets and power loss * Engineers can access diagnostic information locally or remotely The diagnostics subsystem is **non-intrusive**, meaning it shall not block core sensing or communication functions unless the system enters a fatal state. ## 2\. Feature Overview and Relationships

Feature ID

Feature Name

Primary Objective

Related Features

F-DIAG-01

Diagnostic Code Management

Standardize fault and warning identification

DQC, COM

F-DIAG-02

Diagnostic Data Storage

Persist diagnostic events

DP Stack

F-DIAG-03

Diagnostic Session

Engineer access to diagnostics

COM, System Mgmt

## 3\. Functional Feature Descriptions ### 3.1 F-DIAG-01: Diagnostic Code Management **Description** The system shall implement a structured diagnostic code framework to represent system health conditions, warnings, errors, and fatal faults. Each diagnostic event is associated with: * A unique diagnostic code * Severity level (info, warning, error, fatal) * A hierarchical root-cause classification * Timestamp and source component This framework enables consistent fault handling across all system components. **Key Capabilities** * Unique diagnostic code registry * Severity classification * Root-cause hierarchy * Event-based reporting ### 3.2 F-DIAG-02: Diagnostic Data Storage **Description** The system shall persist diagnostic events in non-volatile storage to allow post-failure analysis and long-term health monitoring. Stored diagnostics remain available across system resets and power cycles until explicitly cleared by an authorized diagnostic session or command. **Key Capabilities** * Persistent storage of diagnostic events * Timestamped records * Bounded storage with overwrite policy * Integration with DP / Persistence layer ### 3.3 F-DIAG-03: Diagnostic Session **Description** The system shall provide a diagnostic session that allows authorized engineers or tools to access diagnostic data, inspect system health, and perform maintenance operations. The diagnostic session may be accessed locally or remotely via the communication interface and supports read and limited control operations. **Key Capabilities** * Session-based access * Read diagnostics and health data * Clear diagnostic records * Controlled command execution ## 4\. System Requirements (Formal SHALL Statements) ### 4.1 Diagnostic Code Management **SR-DIAG-001** The system shall implement a diagnostic code framework for reporting system health, warnings, errors, and fatal faults. **SR-DIAG-002** The system shall assign a unique diagnostic code to each detected fault or abnormal condition. **SR-DIAG-003** The system shall classify diagnostic codes by severity level. **SR-DIAG-004** The system shall associate each diagnostic event with a timestamp and source component. ### 4.2 Diagnostic Data Storage **SR-DIAG-005** The system shall persist diagnostic events in non-volatile storage. **SR-DIAG-006** The system shall retain diagnostic data across system resets and power cycles. **SR-DIAG-007** The system shall implement a bounded diagnostic storage mechanism with a defined overwrite or rollover policy. ### 4.3 Diagnostic Session **SR-DIAG-008** The system shall provide a diagnostic session interface for accessing diagnostic data. **SR-DIAG-009** The system shall allow authorized diagnostic sessions to retrieve stored diagnostic events. **SR-DIAG-010** The system shall allow authorized diagnostic sessions to clear diagnostic records. **SR-DIAG-011** The system shall ensure that diagnostic sessions do not interfere with normal sensor acquisition or communication operations. ## 5\. Feature ↔ System Requirement Mapping

Feature ID

System Requirements

F-DIAG-01

SR-DIAG-001, SR-DIAG-002, SR-DIAG-003, SR-DIAG-004

F-DIAG-02

SR-DIAG-005, SR-DIAG-006, SR-DIAG-007

F-DIAG-03

SR-DIAG-008, SR-DIAG-009, SR-DIAG-010, SR-DIAG-011

## 6\. Engineering Notes * Diagnostic codes should be versioned to support firmware evolution. * Diagnostic severity may be linked to LED indicators (green/yellow/red). * Fatal diagnostics may trigger the teardown mechanism defined elsewhere. * Security and access control for diagnostic sessions are handled under **Security & Safety Features**. ##